{"id":971,"date":"2025-05-16T14:58:39","date_gmt":"2025-05-16T14:58:39","guid":{"rendered":"https:\/\/index.kinerjabumdam.org\/?post_type=docs&#038;p=971"},"modified":"2025-06-16T14:18:27","modified_gmt":"2025-06-16T14:18:27","password":"","slug":"aspek-operasi","status":"publish","type":"docs","link":"https:\/\/kinerjabumdam.org\/fp\/docs\/aspek-operasi\/","title":{"rendered":"Aspek Operasi"},"content":{"rendered":"\r\n<h4 class=\"wp-block-heading\">23. <a id=\"PI_O_AM_01\"><\/a>PI_O_AM_01: Prosentase kapasitas produksi saat ini (%) (<em>Percentage of Current Production Capacity<\/em>)<\/h4>\r\n\r\n\r\n\r\n<p><strong>Definisi:<\/strong>\u00a0Perbandingan antara kapasitas produksi riil saat ini dengan kapasitas terpasang (desaiseluruh unit Instalasi Pengolahan Air (IPBUMD-AM.<\/p>\r\n\r\n\r\n\r\n<p><strong>Rumus:<\/strong><\/p>\r\n\r\n\r\n\r\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"602\" height=\"58\" class=\"wp-image-974 aligncenter\" src=\"https:\/\/index.kinerjabumdam.org\/wp-content\/uploads\/2025\/05\/image028.jpg\" alt=\"\" srcset=\"https:\/\/kinerjabumdam.org\/fp\/wp-content\/uploads\/2025\/05\/image028.jpg 602w, https:\/\/kinerjabumdam.org\/fp\/wp-content\/uploads\/2025\/05\/image028-300x29.jpg 300w\" sizes=\"(max-width: 602px) 100vw, 602px\" \/><\/figure>\r\n\r\n\r\n\r\n<p><strong>Data yang Dibutuhkan:<\/strong><\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li><strong>Kapasitas produksi riil saat ini:<\/strong>\u00a0Kapasitas produksi riil semua unit IPA BUMD-AM saat ini (diperoleh dari hasil inspeksi reguler\/tahunan).<\/li>\r\n\r\n\r\n\r\n<li><strong>Kapasitas terpasang:<\/strong>\u00a0Kapasitas terpasang (desaisemua unit IPA BUMD-AM.<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<p><strong>Sumber Data:<\/strong><\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li>Laporan teknik (bagian produksi dan distribusi).<\/li>\r\n\r\n\r\n\r\n<li>Laporan bagian aset.<\/li>\r\n<\/ul>\r\n<p><strong>Standar Perhitungan Nilai:<\/strong><\/p>\r\n<table style=\"width: 100%;\">\r\n<tbody>\r\n<tr>\r\n<td style=\"width: 70.2517%;\"><strong>Besaran\/Kondisi<\/strong><\/td>\r\n<td style=\"width: 29.5195%;\"><strong>Nilai<\/strong><\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">&gt; 90 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">5<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">80-90 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">4<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">70-80 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">3<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">60-70 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">2<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">&lt;60 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">1<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n\r\n\r\n\r\n<h4 class=\"wp-block-heading\">24. <a id=\"PI_O_AM_02\"><\/a>PI_O_AM_02: Tingkat Kehilangan Air Produksi (%) (<em>Production Water Losses<\/em>)<\/h4>\r\n\r\n\r\n\r\n<p><strong>Definisi:<\/strong>\u00a0Persentase selisih antara volume air baku yang diambil dengan volume air produksi riil terhadap volume air baku.<\/p>\r\n\r\n\r\n\r\n<p><strong>Rumus:<\/strong><\/p>\r\n\r\n\r\n\r\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"602\" height=\"55\" class=\"wp-image-975\" src=\"https:\/\/index.kinerjabumdam.org\/wp-content\/uploads\/2025\/05\/image030.jpg\" alt=\"\" srcset=\"https:\/\/kinerjabumdam.org\/fp\/wp-content\/uploads\/2025\/05\/image030.jpg 602w, https:\/\/kinerjabumdam.org\/fp\/wp-content\/uploads\/2025\/05\/image030-300x27.jpg 300w\" sizes=\"(max-width: 602px) 100vw, 602px\" \/><\/figure>\r\n\r\n\r\n\r\n<p><strong>Penjelasan Komponen:<\/strong><\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li><strong>Volume air baku:<\/strong>\u00a0Volume air baku yang diambil dari sumber air dan diolah di IPA (diukur menggunakan\u00a0<em>flow meter<\/em>).<\/li>\r\n\r\n\r\n\r\n<li><strong>Volume produksi riil:<\/strong>\u00a0Volume air terolah yang diproduksi oleh IPA (dapat diketahui dari pembacaan meter induk di reservoir IPA\/jalur pipa distribusi utama, atau melalui perhitungan menggunakan alat ukur Thomson\/Cipoletti, kapasitas reservoir dan waktu pengisian, atau kurva pompa).<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<p><strong>Data yang Dibutuhkan:<\/strong><\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li><strong>Volume air baku:<\/strong>\u00a0Data volume air baku menggunakan\u00a0<em>flow meter<\/em>.<\/li>\r\n\r\n\r\n\r\n<li><strong>Volume produksi riil:<\/strong>\u00a0Data volume air produksi dari meter induk atau perhitungan alternatif.<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<p><strong>Sumber Data:<\/strong><\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li>Laporan teknik (bagian distribusi).<\/li>\r\n\r\n\r\n\r\n<li>Ikhtisar Rekening Air.<\/li>\r\n\r\n\r\n\r\n<li>Neraca Air.<\/li>\r\n<\/ul>\r\n<p><strong>Standar Perhitungan Nilai:<\/strong><\/p>\r\n<table style=\"width: 100%;\">\r\n<tbody>\r\n<tr>\r\n<td style=\"width: 70.2517%;\"><strong>Besaran\/Kondisi<\/strong><\/td>\r\n<td style=\"width: 29.5195%;\"><strong>Nilai<\/strong><\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">\u2264 5 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">5<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">&gt; 5 &#8211; 10 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">4<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">&gt; 5 &#8211; 10 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">3<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">&gt; 15 &#8211; 20 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">2<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">&gt; 20 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">1<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n\r\n\r\n\r\n<h4 class=\"wp-block-heading\">25. <a id=\"PI_O_AM_03\"><\/a>PI_O_AM_03: Air Tidak Berekening\/ATR (%) (<em>Non-Revenue Water\/NRW<\/em>)<\/h4>\r\n\r\n\r\n\r\n<p><strong>Definisi:<\/strong>\u00a0Persentase selisih antara volume air yang masuk sistem distribusi dengan volume air yang tertagih (terjuaselama periode evaluasi terhadap volume distribusi air.<\/p>\r\n\r\n\r\n\r\n<p><strong>Rumus:<\/strong><\/p>\r\n\r\n\r\n\r\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"509\" height=\"62\" class=\"wp-image-976\" src=\"https:\/\/index.kinerjabumdam.org\/wp-content\/uploads\/2025\/05\/image031.png\" alt=\"\" srcset=\"https:\/\/kinerjabumdam.org\/fp\/wp-content\/uploads\/2025\/05\/image031.png 509w, https:\/\/kinerjabumdam.org\/fp\/wp-content\/uploads\/2025\/05\/image031-300x37.png 300w\" sizes=\"(max-width: 509px) 100vw, 509px\" \/><\/figure>\r\n\r\n\r\n\r\n<p><strong>Penjelasan Komponen:<\/strong><\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li><strong>Distribusi air:<\/strong>\u00a0Volume air yang disalurkan kepada pelanggan melalui jaringan pipa distribusi selama periode evaluasi (dapat diketahui dari meter induk di jalur pipa distribusi utama atau perhitungan alternatif seperti penggunaan alat ukur Thomson\/Cipoletti, kapasitas reservoir dan waktu pengisian, atau selisih volume air baku dan volume produksi IPA, atau kurva pompa).<\/li>\r\n\r\n\r\n\r\n<li><strong>Air terjual:<\/strong>\u00a0Volume air yang terpakai oleh pelanggan dan tercatat dalam Ikhtisar Rekening Air (IRselama periode evaluasi (diperoleh dari pembacaan seluruh meter pelanggan).<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<p><strong>Data yang Dibutuhkan:<\/strong><\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li><strong>Volume distribusi air:<\/strong>\u00a0Data volume distribusi air dari meter induk atau perhitungan alternatif.<\/li>\r\n\r\n\r\n\r\n<li><strong>Volume air terjual:<\/strong>\u00a0Volume air terjual dari pembacaan seluruh meter pelanggan.<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<p><strong>Sumber Data:<\/strong><\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li>Laporan teknik (bagian distribusi).<\/li>\r\n\r\n\r\n\r\n<li>Ikhtisar Rekening Air.<\/li>\r\n\r\n\r\n\r\n<li>Neraca Air.<\/li>\r\n<\/ul>\r\n<p><strong>Standar Perhitungan Nilai:<\/strong><\/p>\r\n<table style=\"width: 100%;\">\r\n<tbody>\r\n<tr>\r\n<td style=\"width: 70.2517%;\"><strong>Besaran\/Kondisi<\/strong><\/td>\r\n<td style=\"width: 29.5195%;\"><strong>Nilai<\/strong><\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">\u2264 25 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">5<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">&gt; 25 &#8211; 30 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">4<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">&gt; 30 &#8211; 35 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">3<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">&gt; 35 &#8211; 40 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">2<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">&gt; 40 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">1<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n\r\n\r\n\r\n<h4 class=\"wp-block-heading\">26. <a id=\"PI_O_AM_04\"><\/a>PI_O_AM_04: Tingkat Kehilangan Air Fisik (%) (<em>Physical Water Losses<\/em>)<\/h4>\r\n\r\n\r\n\r\n<p><strong>Definisi:<\/strong>\u00a0Persentase volume air yang hilang secara fisik (kebocoraterhadap volume distribusi air.<\/p>\r\n\r\n\r\n\r\n<p><strong>Rumus:<\/strong><\/p>\r\n\r\n\r\n\r\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"601\" height=\"60\" class=\"wp-image-977\" src=\"https:\/\/index.kinerjabumdam.org\/wp-content\/uploads\/2025\/05\/image033.jpg\" alt=\"\" srcset=\"https:\/\/kinerjabumdam.org\/fp\/wp-content\/uploads\/2025\/05\/image033.jpg 601w, https:\/\/kinerjabumdam.org\/fp\/wp-content\/uploads\/2025\/05\/image033-300x30.jpg 300w\" sizes=\"(max-width: 601px) 100vw, 601px\" \/><\/figure>\r\n\r\n\r\n\r\n<p><strong>Penjelasan Komponen:<\/strong><\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li><strong>Kehilangan air fisik (<em>real losses<\/em>):<\/strong>\u00a0Kebocoran dari pipa transmisi dan distribusi, kebocoran dan limpahan dari reservoir dan tangki penyimpanan, kebocoran pada pipa dinas hingga meter pelanggan.<\/li>\r\n\r\n\r\n\r\n<li><strong>Distribusi air:<\/strong>\u00a0Volume air yang disalurkan kepada pelanggan melalui jaringan pipa distribusi selama periode evaluasi (sama dengan penjelasan pada PI_O_AM_03).<\/li>\r\n\r\n\r\n\r\n<li><strong>Air terjual:<\/strong>\u00a0Volume air yang terpakai oleh pelanggan dan tercatat dalam Ikhtisar Rekening Air (IRselama periode evaluasi (sama dengan penjelasan pada PI_O_AM_03).<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<p><strong>Data yang Dibutuhkan:<\/strong><\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li><strong>Volume air yang hilang yang bersifat fisik:<\/strong>\u00a0Estimasi volume kehilangan air akibat kebocoran.<\/li>\r\n\r\n\r\n\r\n<li><strong>Volume distribusi air:<\/strong>\u00a0Data volume distribusi air dari meter induk atau perhitungan alternatif (sama dengan PI_O_AM_03).<\/li>\r\n\r\n\r\n\r\n<li><strong>Volume air terjual:<\/strong>\u00a0Volume air terjual dari pembacaan seluruh meter pelanggan (sama dengan PI_O_AM_03).<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<p><strong>Sumber Data:<\/strong><\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li>Laporan teknik (bagian distribusi).<\/li>\r\n\r\n\r\n\r\n<li>Neraca Air.<\/li>\r\n\r\n\r\n\r\n<li>Ikhtisar Rekening Air.<\/li>\r\n<\/ul>\r\n<p><strong>Standar Perhitungan Nilai:<\/strong><\/p>\r\n<table style=\"width: 100%;\">\r\n<tbody>\r\n<tr>\r\n<td style=\"width: 70.2517%;\"><strong>Besaran\/Kondisi<\/strong><\/td>\r\n<td style=\"width: 29.5195%;\"><strong>Nilai<\/strong><\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">\u2264 25 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">5<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">&gt; 25 &#8211; 30 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">4<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">&gt; 30 &#8211; 35 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">3<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">&gt; 35 &#8211; 40 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">2<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">&gt; 40 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">1<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n\r\n\r\n\r\n<h4 class=\"wp-block-heading\">27.\u00a0 <a id=\"PI_O_AM_05\"><\/a>PI_O_AM_05: Tingkat Kehilangan Air Komersial (%) (<em>Commercial Water Losses<\/em>)<\/h4>\r\n\r\n\r\n\r\n<p><strong>Definisi:<\/strong>\u00a0Persentase volume air yang hilang secara komersial (<em>apparent losse<\/em>terhadap volume distribusi air.<\/p>\r\n\r\n\r\n\r\n<p><strong>Rumus:<\/strong><\/p>\r\n\r\n\r\n\r\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"602\" height=\"55\" class=\"wp-image-978\" src=\"https:\/\/index.kinerjabumdam.org\/wp-content\/uploads\/2025\/05\/image035.jpg\" alt=\"\" srcset=\"https:\/\/kinerjabumdam.org\/fp\/wp-content\/uploads\/2025\/05\/image035.jpg 602w, https:\/\/kinerjabumdam.org\/fp\/wp-content\/uploads\/2025\/05\/image035-300x27.jpg 300w\" sizes=\"(max-width: 602px) 100vw, 602px\" \/><\/figure>\r\n\r\n\r\n\r\n<p><strong>Penjelasan Komponen:<\/strong><\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li><strong>Kehilangan air komersial (<em>apparent losses<\/em>):<\/strong>\u00a0Air yang dikonsumsi namun tidak dibayar, meliputi ketidakakuratan meter pelanggan, konsumsi tidak resmi, kesalahan pembacaan meter, kesalahan penanganan data dan pembukuan.<\/li>\r\n\r\n\r\n\r\n<li><strong>Distribusi air:<\/strong>\u00a0Volume air yang disalurkan kepada pelanggan melalui jaringan pipa distribusi selama periode evaluasi (sama dengan penjelasan pada PI_O_AM_03).<\/li>\r\n\r\n\r\n\r\n<li><strong>Air terjual:<\/strong>\u00a0Volume air yang terpakai oleh pelanggan dan tercatat dalam Ikhtisar Rekening Air (IRselama periode evaluasi (sama dengan penjelasan pada PI_O_AM_03).<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<p><strong>Data yang Dibutuhkan:<\/strong><\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li><strong>Volume air yang hilang yang bersifat komersial:<\/strong>\u00a0Estimasi volume kehilangan air akibat faktor komersial.<\/li>\r\n\r\n\r\n\r\n<li><strong>Volume distribusi air:<\/strong>\u00a0Data volume distribusi air dari meter induk atau perhitungan alternatif (sama dengan PI_O_AM_03).<\/li>\r\n\r\n\r\n\r\n<li><strong>Volume air terjual:<\/strong>\u00a0Volume air terjual dari pembacaan seluruh meter pelanggan (sama dengan PI_O_AM_03).<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<p><strong>Sumber Data:<\/strong><\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li>Laporan teknik (bagian distribusi).<\/li>\r\n\r\n\r\n\r\n<li>Ikhtisar Rekening Air.<\/li>\r\n\r\n\r\n\r\n<li>Neraca Air.<\/li>\r\n<\/ul>\r\n<p><strong>Standar Perhitungan Nilai:<\/strong><\/p>\r\n<table style=\"width: 100%;\">\r\n<tbody>\r\n<tr>\r\n<td style=\"width: 70.2517%;\"><strong>Besaran\/Kondisi<\/strong><\/td>\r\n<td style=\"width: 29.5195%;\"><strong>Nilai<\/strong><\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">\u2264 25 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">5<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">&gt; 25 &#8211; 30 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">4<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">&gt; 30 &#8211; 35 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">3<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">&gt; 35 &#8211; 40 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">2<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">&gt; 40 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">1<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n\r\n\r\n\r\n<h4 class=\"wp-block-heading\">28.\u00a0 <a id=\"PI_O_AM_06\"><\/a>PI_O_AM_06: Prosentase pemasangan Meter Air Induk (%) (<em>Percentage of Bulk Water Meter Installation<\/em>)<\/h4>\r\n\r\n\r\n\r\n<p><strong>Definisi:<\/strong>\u00a0Persentase jumlah meter air induk yang terpasang dan berfungsi di unit produksi (IPA\/Reservoidan transmisi\/distribusi (DMterhadap total jumlah IPA dan DMA.<\/p>\r\n\r\n\r\n\r\n<p><strong>Rumus:<\/strong><\/p>\r\n\r\n\r\n\r\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"568\" height=\"84\" class=\"wp-image-979\" src=\"https:\/\/index.kinerjabumdam.org\/wp-content\/uploads\/2025\/05\/image036.png\" alt=\"\" srcset=\"https:\/\/kinerjabumdam.org\/fp\/wp-content\/uploads\/2025\/05\/image036.png 568w, https:\/\/kinerjabumdam.org\/fp\/wp-content\/uploads\/2025\/05\/image036-300x44.png 300w\" sizes=\"(max-width: 568px) 100vw, 568px\" \/><\/figure>\r\n\r\n\r\n\r\n<p><strong>Penjelasan Komponen:<\/strong><\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li><strong>Jumlah Meter Induk Terpasang:<\/strong>\u00a0Jumlah meter air induk yang terpasang dan berfungsi di semua Unit Produksi dan Transmisi\/Distribusi.<\/li>\r\n\r\n\r\n\r\n<li><strong>Jumlah IPA:<\/strong>\u00a0Jumlah semua IPA yang dimiliki BUMD-AM.<\/li>\r\n\r\n\r\n\r\n<li><strong>Jumlah DMA:<\/strong>\u00a0Jumlah\u00a0<em>District Metered Area<\/em>\u00a0(DMyang dimiliki oleh BUMD-AM.<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<p><strong>Data yang Dibutuhkan:<\/strong><\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li><strong>Jumlah meter induk terpasang:<\/strong>\u00a0Banyaknya meter air induk yang terpasang di semua unit produksi (IPA\/Reservoidan transmisi\/distribusi (DMA).<\/li>\r\n\r\n\r\n\r\n<li><strong>Jumlah IPA dan Jumlah DMA:<\/strong>\u00a0Banyaknya unit IPA dan DMA yang dimiliki BUMD-AM.<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<p><strong>Sumber Data:<\/strong><\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li>Laporan teknik (bagian produksi dan distribusi).<\/li>\r\n\r\n\r\n\r\n<li>Laporan bagian aset.<\/li>\r\n<\/ul>\r\n<p><strong>Standar Perhitungan Nilai:<\/strong><\/p>\r\n<table style=\"width: 100%;\">\r\n<tbody>\r\n<tr>\r\n<td style=\"width: 70.2517%;\"><strong>Besaran\/Kondisi<\/strong><\/td>\r\n<td style=\"width: 29.5195%;\"><strong>Nilai<\/strong><\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">100 %<\/td>\r\n<td style=\"width: 29.5195%;\">5<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">60 &#8211; &lt;100 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">4<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">30 &#8211; &lt;60 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">3<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">&gt;0 &#8211; &lt;30 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">2<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">0 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">1<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n\r\n\r\n\r\n<h4 class=\"wp-block-heading\">29. <a id=\"PI_O_AM_07\"><\/a>PI_O_AM_07: Penggantian dan Kalibrasi Meter Air Pelanggan (%) (<em>Customer Water Meter Replacement and Calibration<\/em>)<\/h4>\r\n\r\n\r\n\r\n<p><strong>Definisi:<\/strong>\u00a0Persentase jumlah meter air pelanggan yang diganti dan\/atau dikalibrasi selama periode evaluasi terhadap total jumlah pelanggan aktif.<\/p>\r\n\r\n\r\n\r\n<p><strong>Rumus:<\/strong><\/p>\r\n\r\n\r\n\r\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"574\" height=\"75\" class=\"wp-image-980\" src=\"https:\/\/index.kinerjabumdam.org\/wp-content\/uploads\/2025\/05\/image037.png\" alt=\"\" srcset=\"https:\/\/kinerjabumdam.org\/fp\/wp-content\/uploads\/2025\/05\/image037.png 574w, https:\/\/kinerjabumdam.org\/fp\/wp-content\/uploads\/2025\/05\/image037-300x39.png 300w\" sizes=\"(max-width: 574px) 100vw, 574px\" \/><\/figure>\r\n\r\n\r\n\r\n<h4 class=\"wp-block-heading\">Penggantian\u00a0dan\u00a0Kalibrasi\u00a0Meter\u00a0Air\u00a0Pelanggan=\u00a0(Jumlah\u00a0meter\u00a0air\u00a0pelanggan\u00a0yang\u00a0diganti\u00a0dan\/atau\u00a0yang\u00a0dikalibrasi\u00a0(unit))\/\u00a0Jumlah\u00a0pelanggan\u00a0(SL)\u200b\u00d7100%<\/h4>\r\n\r\n\r\n\r\n<p><strong>Penjelasan Komponen:<\/strong><\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li><strong>Jumlah meter air yang diganti atau dikalibrasi:<\/strong>\u00a0Banyaknya meter air pelanggan yang diganti baru atau dikalibrasi selama periode evaluasi.<\/li>\r\n\r\n\r\n\r\n<li><strong>Jumlah pelanggan:<\/strong>\u00a0Banyaknya pelanggan aktif.<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<p><strong>Data yang Dibutuhkan:<\/strong><\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li><strong>Jumlah meter air pelanggan yang diganti atau dikalibrasi:<\/strong>\u00a0Data banyaknya meter pelanggan yang diganti baru atau dikalibrasi selama periode evaluasi.<\/li>\r\n\r\n\r\n\r\n<li><strong>Jumlah pelanggan:<\/strong>\u00a0Data jumlah pelanggan aktif dari bagian hubungan langganan.<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<p><strong>Sumber Data:<\/strong>\u00a0Laporan teknik (bagian pelayanan pengaduan pelanggan).<\/p>\r\n<p><strong>Standar Perhitungan Nilai:<\/strong><\/p>\r\n<table style=\"width: 100%;\">\r\n<tbody>\r\n<tr>\r\n<td style=\"width: 70.2517%;\"><strong>Besaran\/Kondisi<\/strong><\/td>\r\n<td style=\"width: 29.5195%;\"><strong>Nilai<\/strong><\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">\u2265 20 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">5<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">15 &#8211; &lt; 20 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">4<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">10 &#8211; &lt; 15 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">3<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">5 &#8211; &lt; 10 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">2<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">&lt; 5 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">1<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n\r\n\r\n\r\n<h4 class=\"wp-block-heading\">30. <a id=\"PI_O_AM_08\"><\/a>PI_O_AM_08: Pemeriksaan Parameter Mikrobiologi yang Dilakukan (%) (<em>Microbiological Parameters Tests Carried Out<\/em>)<\/h4>\r\n\r\n\r\n\r\n<p><strong>Definisi:<\/strong>\u00a0Persentase jumlah sampel pemeriksaan mikrobiologi yang dilakukan di titik pelanggan dibandingkan dengan jumlah sampel pemeriksaan mikrobiologi yang dipersyaratkan sesuai Permenkes Nomor 002\/MENKES\/PER\/I\/2023.<\/p>\r\n\r\n\r\n\r\n<p><strong>Rumus:<\/strong><\/p>\r\n\r\n\r\n\r\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"572\" height=\"84\" class=\"wp-image-981 aligncenter\" src=\"https:\/\/index.kinerjabumdam.org\/wp-content\/uploads\/2025\/05\/image038.png\" alt=\"\" srcset=\"https:\/\/kinerjabumdam.org\/fp\/wp-content\/uploads\/2025\/05\/image038.png 572w, https:\/\/kinerjabumdam.org\/fp\/wp-content\/uploads\/2025\/05\/image038-300x44.png 300w\" sizes=\"(max-width: 572px) 100vw, 572px\" \/><\/figure>\r\n\r\n\r\n\r\n<p><strong>Penjelasan Komponen:<\/strong><\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li><strong>Jumlah sampel pemeriksaan mikrobiologi yang dilakukan:<\/strong>\u00a0Banyaknya sampel air minum yang diambil di titik pelanggan dan dilakukan pemeriksaan parameter wajib mikrobiologi menurut Permenkes Nomor 002\/MENKES\/PER\/I\/2023.<\/li>\r\n\r\n\r\n\r\n<li><strong>Jumlah sampel pemeriksaan mikrobiologi yang dipersyaratkan:<\/strong>\u00a0Jumlah uji kualitas sampel berkala untuk air minum dengan sistem perpipaan di jaringan distribusi (titik pelanggayang harus dilakukan untuk pengawasan internal dengan frekuensi minimal sesuai Lampiran Permenkes Nomor 002\/MENKES\/PER\/I\/2023 BAB III untuk parameter wajib mikrobiologi.<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<p><strong>Data yang Dibutuhkan:<\/strong>\u00a0Jumlah pengambilan sampel yang dilakukan di sambungan pelanggan untuk pengawasan internal dan dilakukan pemeriksaan\/pengujian di laboratorium dengan kriteria jumlah dan frekuensi pengambilan sampel serta kriteria laboratorium yang sesuai Permenkes Nomor 002\/MENKES\/PER\/I\/2023.<\/p>\r\n\r\n\r\n\r\n<p><strong>Sumber Data:<\/strong>\u00a0Laporan hasil pengambilan sampel dan uji laboratorium untuk pengawasan internal yang dilakukan oleh BUMD-AM di laboratorium yang terakreditasi dan teregistrasi di Kementerian Kesehatan. Jika tidak tersedia laboratorium terakreditasi dan teregistrasi, Pemerintah Daerah dapat menetapkan laboratorium pengujian air.<\/p>\r\n<p><strong>Standar Perhitungan Nilai:<\/strong><\/p>\r\n<table style=\"width: 100%;\">\r\n<tbody>\r\n<tr>\r\n<td style=\"width: 70.2517%;\"><strong>Besaran\/Kondisi<\/strong><\/td>\r\n<td style=\"width: 29.5195%;\"><strong>Nilai<\/strong><\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">100 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">5<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">80 &#8211; &lt; 100 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">4<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">60 &#8211; &lt; 80 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">3<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">40 &#8211; &lt; 60 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">2<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">&lt; 40 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">1<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n\r\n\r\n\r\n<h4 class=\"wp-block-heading\">31.\u00a0PI_O_AM_09: Pemeriksaan Parameter Fisik dan Kimia yang Dilakukan (%) (<em>Phisical and Chemical Parameters Tests Carried Out<\/em>)<\/h4>\r\n\r\n\r\n\r\n<p><strong>Definisi:<\/strong>\u00a0Persentase jumlah sampel pemeriksaan parameter fisik dan kimia yang dilakukan di titik pelanggan dibandingkan dengan jumlah sampel pemeriksaan parameter fisik dan kimia yang dipersyaratkan sesuai Permenkes Nomor 002\/MENKES\/PER\/I\/2023.<\/p>\r\n\r\n\r\n\r\n<p><strong>Rumus:<\/strong><\/p>\r\n\r\n\r\n\r\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"612\" height=\"73\" class=\"wp-image-982\" src=\"https:\/\/index.kinerjabumdam.org\/wp-content\/uploads\/2025\/05\/image039.png\" alt=\"\" srcset=\"https:\/\/kinerjabumdam.org\/fp\/wp-content\/uploads\/2025\/05\/image039.png 612w, https:\/\/kinerjabumdam.org\/fp\/wp-content\/uploads\/2025\/05\/image039-300x36.png 300w\" sizes=\"(max-width: 612px) 100vw, 612px\" \/><\/figure>\r\n\r\n\r\n\r\n<p><strong>Penjelasan Komponen:<\/strong><\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li><strong>Jumlah sampel pemeriksaan fisik dan kimia yang dilakukan:<\/strong>\u00a0Banyaknya sampel air minum yang diambil di titik pelanggan dan dilakukan pemeriksaan parameter wajib fisik dan kimia menurut Permenkes Nomor 002\/MENKES\/PER\/I\/2023.<\/li>\r\n\r\n\r\n\r\n<li><strong>Jumlah sampel pemeriksaan fisik dan kimia yang dipersyaratkan:<\/strong>\u00a0Jumlah uji kualitas sampel berkala untuk air minum dengan sistem perpipaan di jaringan distribusi (titik pelanggayang harus dilakukan untuk pengawasan internal dengan frekuensi minimal sesuai Lampiran Permenkes Nomor 002\/MENKES\/PER\/I\/2023 BAB III untuk parameter wajib fisik dan kimia.<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<p><strong>Data yang Dibutuhkan:<\/strong>\u00a0Jumlah pengambilan sampel yang dilakukan di sambungan pelanggan untuk pengawasan internal dan dilakukan pemeriksaan\/pengujian di laboratorium dengan kriteria jumlah dan frekuensi pengambilan sampel serta kriteria laboratorium yang sesuai Permenkes Nomor 002\/MENKES\/PER\/I\/2023.<\/p>\r\n\r\n\r\n\r\n<p><strong>Sumber Data:<\/strong>\u00a0Laporan hasil pengambilan sampel dan uji laboratorium untuk pengawasan internal yang dilakukan oleh BUMD-AM di laboratorium yang terakreditasi dan teregistrasi di Kementerian Kesehatan. Jika tidak tersedia laboratorium terakreditasi dan teregistrasi, Pemerintah Daerah dapat menetapkan laboratorium pengujian air.<\/p>\r\n<p>&nbsp;<\/p>\r\n<p><strong>Standar Perhitungan Nilai:<\/strong><\/p>\r\n<table style=\"width: 100%;\">\r\n<tbody>\r\n<tr>\r\n<td style=\"width: 70.2517%;\"><strong>Besaran\/Kondisi<\/strong><\/td>\r\n<td style=\"width: 29.5195%;\"><strong>Nilai<\/strong><\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">100 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">5<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">80 &#8211; &lt; 100 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">4<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">60 &#8211; &lt; 80 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">3<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">40 &#8211; &lt; 60 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">2<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">&lt; 40 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">1<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n\r\n\r\n\r\n<h4 class=\"wp-block-heading\">32. <a id=\"PI_O_AM_10\"><\/a>PI_O_AM_10: Peningkatan Efisiensi Energi (%) (<em>Improvement Energy Efficiency<\/em>)<\/h4>\r\n\r\n\r\n\r\n<p><strong>Definisi:<\/strong>\u00a0Persentase penurunan penggunaan energi per unit volume air yang diproduksi dan didistribusikan dibandingkan dengan tahun sebelumnya.<\/p>\r\n\r\n\r\n\r\n<p><strong>Rumus:<\/strong><\/p>\r\n\r\n\r\n\r\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"602\" height=\"80\" class=\"wp-image-983\" src=\"https:\/\/index.kinerjabumdam.org\/wp-content\/uploads\/2025\/05\/image041.jpg\" alt=\"\" srcset=\"https:\/\/kinerjabumdam.org\/fp\/wp-content\/uploads\/2025\/05\/image041.jpg 602w, https:\/\/kinerjabumdam.org\/fp\/wp-content\/uploads\/2025\/05\/image041-300x40.jpg 300w\" sizes=\"(max-width: 602px) 100vw, 602px\" \/><\/figure>\r\n\r\n\r\n\r\n<p><strong>Penjelasan Komponen:<\/strong><\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li><strong>Penggunaan energi tahun lalu:<\/strong>\u00a0Total energi (kWyang digunakan untuk keperluan produksi, distribusi, dan perkantoran BUMD-AM pada periode evaluasi kinerja tahun sebelumnya.<\/li>\r\n\r\n\r\n\r\n<li><strong>Penggunaan energi tahun ini:<\/strong>\u00a0Total energi (kWyang digunakan untuk keperluan produksi, distribusi, dan perkantoran BUMD-AM pada periode evaluasi kinerja tahun ini.<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<p><strong>Data yang Dibutuhkan:<\/strong><\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li><strong>Penggunaan energi tahun ini:<\/strong>\u00a0Data jumlah energi yang digunakan pada periode evaluasi kinerja saat ini.<\/li>\r\n\r\n\r\n\r\n<li><strong>Penggunaan energi tahun lalu:<\/strong>\u00a0Data jumlah energi yang digunakan pada periode evaluasi kinerja tahun sebelumnya.<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<p><strong>Sumber Data:<\/strong><\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li>Laporan teknik (bagian produksi dan distribustahun ini.<\/li>\r\n\r\n\r\n\r\n<li>Laporan keuangan tahun ini.<\/li>\r\n\r\n\r\n\r\n<li>Laporan evaluasi kinerja tahun sebelumnya.<\/li>\r\n<\/ul>\r\n<p><strong>Standar Perhitungan Nilai:<\/strong><\/p>\r\n<table style=\"width: 100%; height: 312px;\">\r\n<tbody>\r\n<tr style=\"height: 52px;\">\r\n<td style=\"width: 70.2517%; height: 52px;\"><strong>Besaran\/Kondisi<\/strong><\/td>\r\n<td style=\"width: 29.5195%; height: 52px;\"><strong>Nilai<\/strong><\/td>\r\n<\/tr>\r\n<tr style=\"height: 52px;\">\r\n<td style=\"width: 70.2517%; height: 52px;\">\u2265 5 (%)<\/td>\r\n<td style=\"width: 29.5195%; height: 52px;\">5<\/td>\r\n<\/tr>\r\n<tr style=\"height: 52px;\">\r\n<td style=\"width: 70.2517%; height: 52px;\">&gt; 3 &#8211; 5 (%)<\/td>\r\n<td style=\"width: 29.5195%; height: 52px;\">4<\/td>\r\n<\/tr>\r\n<tr style=\"height: 52px;\">\r\n<td style=\"width: 70.2517%; height: 52px;\">&gt; 1 &#8211; 3 (%)<\/td>\r\n<td style=\"width: 29.5195%; height: 52px;\">3<\/td>\r\n<\/tr>\r\n<tr style=\"height: 52px;\">\r\n<td style=\"width: 70.2517%; height: 52px;\">&gt; 0 &#8211; 1 (%)<\/td>\r\n<td style=\"width: 29.5195%; height: 52px;\">2<\/td>\r\n<\/tr>\r\n<tr style=\"height: 52px;\">\r\n<td style=\"width: 70.2517%; height: 52px;\">\u2264 0%<\/td>\r\n<td style=\"width: 29.5195%; height: 52px;\">1<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n\r\n\r\n\r\n\r\n\r\n<h4 class=\"wp-block-heading\">33.\u00a0 <a id=\"PI_O_AM_11\"><\/a>PI_O_AM_11: Penggunaan Energi Terbarukan (%) (<em>Renewable Energy Use<\/em>)<\/h4>\r\n\r\n\r\n\r\n<p><strong>Definisi:<\/strong>\u00a0Persentase energi yang digunakan dari sumber terbarukan (tenaga surya, angin, air, biologi, dan panas bumi yang diusahakan sendirterhadap total penggunaan energi BUMD-AM.<\/p>\r\n\r\n\r\n\r\n<p><strong>Rumus:<\/strong><\/p>\r\n\r\n\r\n\r\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"602\" height=\"53\" class=\"wp-image-984\" src=\"https:\/\/index.kinerjabumdam.org\/wp-content\/uploads\/2025\/05\/image043.jpg\" alt=\"\" srcset=\"https:\/\/kinerjabumdam.org\/fp\/wp-content\/uploads\/2025\/05\/image043.jpg 602w, https:\/\/kinerjabumdam.org\/fp\/wp-content\/uploads\/2025\/05\/image043-300x26.jpg 300w\" sizes=\"(max-width: 602px) 100vw, 602px\" \/><\/figure>\r\n\r\n\r\n\r\n<p><strong>Penjelasan Komponen:<\/strong><\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li><strong>Jumlah energi terbarukan yang digunakan:<\/strong>\u00a0Total energi (kWyang dihasilkan dan digunakan dari tenaga surya, tenaga angin, arus air, proses biologi, dan panas bumi yang diusahakan sendiri oleh BUMD-AM (bukan dari PLN).<\/li>\r\n\r\n\r\n\r\n<li><strong>Jumlah penggunaan energi:<\/strong>\u00a0Total energi (kWyang digunakan untuk keperluan produksi, distribusi, dan perkantoran BUMD-AM (sama dengan penjelasan pada PI_O_AM_10).<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<p><strong>Data yang Dibutuhkan:<\/strong><\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li><strong>Jumlah energi terbaharukan yang digunakan:<\/strong>\u00a0Data kWh yang dihasilkan dari sumber energi terbarukan yang diusahakan BUMD-AM.<\/li>\r\n\r\n\r\n\r\n<li><strong>Jumlah energi yang digunakan:<\/strong>\u00a0Data jumlah energi yang digunakan (sama dengan PI_O_AM_10).<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<p><strong>Sumber Data:<\/strong><\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li>Laporan teknik (bagian produksi dan distribusi).<\/li>\r\n\r\n\r\n\r\n<li>Laporan keuangan.<\/li>\r\n<\/ul>\r\n<p><strong>Standar Perhitungan Nilai:<\/strong><\/p>\r\n<table style=\"width: 100%;\">\r\n<tbody>\r\n<tr>\r\n<td style=\"width: 70.2517%;\"><strong>Besaran\/Kondisi<\/strong><\/td>\r\n<td style=\"width: 29.5195%;\"><strong>Nilai<\/strong><\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">\u2265 50 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">5<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">&gt; 30 &#8211; 50 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">4<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">&gt; 10 &#8211; 30 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">3<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">&gt; 0 &#8211; 10 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">2<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">0 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">1<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n\r\n\r\n\r\n<h4 class=\"wp-block-heading\"><strong>34. <a id=\"PI_O_AM_12\"><\/a>PI_O_AM_12: Ketahanan Infrastruktur Air (<em>Resilient of Water Infrastructure from Climate Risk<\/em>)<\/strong><\/h4>\r\n\r\n\r\n\r\n<p><strong>Definisi:<\/strong>\u00a0Upaya dan tindakan yang dilakukan BUMD-AM untuk meningkatkan ketahanan infrastruktur air terhadap risiko perubahan iklim (kekeringan, banjir, tanah longsor).<\/p>\r\n\r\n\r\n\r\n<p><strong>Ketentuan:<\/strong><\/p>\r\n\r\n\r\n\r\n<ol class=\"wp-block-list\" style=\"list-style-type: lower-alpha;\">\r\n<li><strong>Ketahanan terkait kuantitas air:<\/strong>\r\n<ul class=\"wp-block-list\">\r\n<li>Menggunakan alternatif sumber air baku (air hujan, air laut, daur ulang\u00a0<em>backwash<\/em>, daur ulang efluen).<\/li>\r\n\r\n\r\n\r\n<li>Mengembangkan program efisiensi penggunaan air untuk berbagai kelompok pengguna, termasuk sosialisasi penghematan air.<\/li>\r\n<\/ul>\r\n<\/li>\r\n\r\n\r\n\r\n<li><strong>Ketahanan terkait kualitas air baku:<\/strong>\r\n<ul class=\"wp-block-list\">\r\n<li>Berperan serta dalam program penghijauan.<\/li>\r\n\r\n\r\n\r\n<li>Berperan serta dalam program pencegahan pencemaran sumber air.<\/li>\r\n\r\n\r\n\r\n<li>Konstruksi bak pra-sedimentasi untuk mengatasi kekeruhan tinggi.<\/li>\r\n<\/ul>\r\n<\/li>\r\n\r\n\r\n\r\n<li><strong>Pengembangan dan penerapan rencana kontinjensi dan kesiapsiagaan:<\/strong>\r\n<ul class=\"wp-block-list\">\r\n<li>Mengembangkan rencana tanggap darurat (termasuk instruksi staf).<\/li>\r\n\r\n\r\n\r\n<li>Pelatihan pegawai dalam menghadapi kondisi bencana\/kedaruratan.<\/li>\r\n\r\n\r\n\r\n<li>Menyimpan suku cadang dan perlengkapan darurat.<\/li>\r\n\r\n\r\n\r\n<li>Mengembangkan rencana komunikasi dan sistem peringatan dini terkait banjir dan kekeringan.<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ol>\r\n\r\n\r\n\r\n<p><strong>Data yang Dibutuhkan:<\/strong><\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li><strong>Diversifikasi sumber air:<\/strong>\u00a0Data sumber air baku yang digunakan BUMD-AM.<\/li>\r\n\r\n\r\n\r\n<li><strong>Adaptasi infrastruktur air dari dampak banjir, tanah longsor, kekeringan:<\/strong>\u00a0Data bangunan pada unit air baku dan unit produksi.<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<p><strong>Sumber Data:<\/strong><\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li>Laporan teknik (bagian air baku dan produksi).<\/li>\r\n\r\n\r\n\r\n<li>RPAM (Rencana Pengamanan Air Minudan Studi Adaptasi dan Mitigasi Perubahan Iklim yang dilakukan BUMD-AM.<\/li>\r\n<\/ul>\r\n<p><strong>Standar Perhitungan Nilai:<\/strong><\/p>\r\n<table style=\"width: 100%;\">\r\n<tbody>\r\n<tr>\r\n<td style=\"width: 70.2517%;\"><strong>Besaran\/Kondisi<\/strong><\/td>\r\n<td style=\"width: 29.5195%;\"><strong>Nilai<\/strong><\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">Melakukan 4 atau lebih kegiatan dari poin (a) dan\/atau poin (b) dan\/atau poin (c)<\/td>\r\n<td style=\"width: 29.5195%;\">5<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">Melakukan 3 kegiatan dari poin (a) dan\/atau poin (b) dan\/atau poin (c)<\/td>\r\n<td style=\"width: 29.5195%;\">4<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">Melakukan 2 kegiatan dari poin (a) dan\/atau poin (b) dan\/atau poin (c)<\/td>\r\n<td style=\"width: 29.5195%;\">3<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">Melakukan 1 kegiatan dari poin (a) atau poin (b) atau poin (c)<\/td>\r\n<td style=\"width: 29.5195%;\">2<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">Tidak melakukan kegiatan poin (a) maupun (b) maupun poin (c)<\/td>\r\n<td style=\"width: 29.5195%;\">1<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n\r\n\r\n\r\n<h4 class=\"wp-block-heading\">34. <a id=\"PI_O_AM_13:\"><\/a>PI_O_AM_13: Rasio Kualitas Air Produksi (%) (<em>Ratio of Production Water Quality<\/em>)<\/h4>\r\n\r\n\r\n\r\n<p><strong>Definisi:<\/strong>\u00a0Persentase jumlah uji air produksi yang memenuhi standar kualitas air minum sesuai Permenkes Nomor 002\/MENKES\/PER\/I\/2023 terhadap total jumlah uji air produksi yang dilakukan.<\/p>\r\n<p>Kualitas air produksi merupakan ukuran yang digunakan untuk mengetahui apakah kualitas air yang diproduksi oleh BUMD-AM telah memenuhi kualitas air minum seperti yang ditetapkan dalam Permenkes Nomor 002\/MENKES\/PER\/I\/2023 tentang Peraturan Pelaksanaan Peraturan Pemerintah Nomor 66 Tahun 2014 tentang Kesehatan Lingkungan, terutama yang terkait dengan Standard Baku Mutu Kesehatan Lingkungan (SBMKL) Air Minum dengan Pedoman terdapat di Lampiran Peraturan tersebut.<br \/>a) Jumlah uji Air Produksi yang memenuhi syarat adalah kualitas air produksi yang memenuhi kualitas parameter wajib air minum menurut PerMenKes No 002\/MENKES\/PER\/I\/2023. Mengingat sebagian perancangan IPA yang dimiliki SPAM-BUMD AM hanya dapat mengolah sebagian aspek dari fisika, dan mikrobiologis saja, sementara untuk aspek kimiawi dan radioaktif hampir seluruh SPAM-BUMD AM belum melengkapinya, maka pendekatan penilaian hanya untuk parameter wajib air minum yang terdiri dari 19 jenis parameter menurut ketentuan Permenkes, yang terdapat pada Lampiran Permenkes Nomor 002\/MENKES\/PER\/I\/2023, BAB II,Tabel 1 seperti berikut.<\/p>\r\n\r\n\r\n\r\n<p><strong>Rumus:<\/strong><\/p>\r\n\r\n\r\n\r\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"602\" height=\"49\" class=\"wp-image-985 aligncenter\" src=\"https:\/\/index.kinerjabumdam.org\/wp-content\/uploads\/2025\/05\/image045.jpg\" alt=\"\" srcset=\"https:\/\/kinerjabumdam.org\/fp\/wp-content\/uploads\/2025\/05\/image045.jpg 602w, https:\/\/kinerjabumdam.org\/fp\/wp-content\/uploads\/2025\/05\/image045-300x24.jpg 300w\" sizes=\"(max-width: 602px) 100vw, 602px\" \/><\/figure>\r\n\r\n\r\n\r\n<p><strong>Penjelasan Komponen:<\/strong><\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li><strong>Jumlah uji Air Produksi yang memenuhi syarat:<\/strong>\u00a0Jumlah uji kualitas air produksi yang memenuhi standar parameter wajib air minum menurut Permenkes Nomor 002\/MENKES\/PER\/I\/2023. Penilaian hanya untuk 19 parameter wajib air minum (Lampiran Permenkes BAB II Tabel 1).<\/li>\r\n\r\n\r\n\r\n<li><strong>Jumlah yang diuji:<\/strong>\u00a0Jumlah uji kualitas sampel berkala untuk air minum dengan sistem perpipaan di unit produksi yang harus dilakukan untuk pengawasan internal dengan frekuensi minimal sesuai Lampiran Permenkes Nomor 002\/MENKES\/PER\/I\/2023 BAB III.<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<p><strong>Data yang Dibutuhkan:<\/strong> Hasil pengujian kualitas air di Unit Produksi (IPA) yang diperoleh dari pengambilan sampel untuk pengawasan internal dengan kriteria jumlah dan frekuensi pengambilan sampel sesuai Permenkes Nomor 002\/MENKES\/PER\/I\/2023.<\/p>\r\n\r\n\r\n\r\n<p><strong>Sumber Data:<\/strong>\u00a0Laporan hasil uji laboratorium untuk pengawasan internal yang dilakukan oleh BUMD-AM di laboratorium yang terakreditasi dan teregistrasi di Kementerian Kesehatan. Jika tidak tersedia laboratorium terakreditasi dan teregistrasi, Pemerintah Daerah dapat menetapkan laboratorium pengujian air.<\/p>\r\n<p><strong>Standar Perhitungan Nilai:<\/strong><\/p>\r\n<table style=\"width: 100%;\">\r\n<tbody>\r\n<tr>\r\n<td style=\"width: 70.2517%;\"><strong>Besaran\/Kondisi<\/strong><\/td>\r\n<td style=\"width: 29.5195%;\"><strong>Nilai<\/strong><\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">\u226580 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">5<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">60 &#8211; &lt; 80 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">4<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">40 &#8211; &lt; 60 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">3<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">20 &#8211; &lt; 40 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">2<\/td>\r\n<\/tr>\r\n<tr>\r\n<td style=\"width: 70.2517%;\">&lt; 20 (%)<\/td>\r\n<td style=\"width: 29.5195%;\">1<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n<p>&nbsp;<\/p>\r\n\r\n\r\n","protected":false},"excerpt":{"rendered":"<p>23. PI_O_AM_01: Prosentase kapasitas produksi saat ini (%) (Percentage of Current Production Capacity) Definisi:\u00a0Perbandingan antara kapasitas produksi riil saat ini dengan kapasitas terpasang (desaiseluruh unit Instalasi Pengolahan Air (IPBUMD-AM. Rumus: Data yang Dibutuhkan: Sumber Data: 24. PI_O_AM_02: Tingkat Kehilangan Air Produksi (%) (Production Water Losses) Definisi:\u00a0Persentase selisih antara volume air baku yang diambil dengan volume [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"_uag_custom_page_level_css":"","_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"doc_category":[12],"doc_tag":[],"class_list":["post-971","docs","type-docs","status-publish","hentry","doc_category-inkenam"],"aioseo_notices":[],"year_month":"2026-04","word_count":2284,"total_views":0,"reactions":{"happy":0,"normal":0,"sad":0},"author_info":{"name":"rietiana@gmail.com","author_nicename":"rietianagmail-com","author_url":"https:\/\/kinerjabumdam.org\/fp\/author\/rietianagmail-com\/"},"doc_category_info":[{"term_name":"Indikator Kinerja Air Minum","term_url":"https:\/\/kinerjabumdam.org\/fp\/docs-category\/inkenam\/"}],"doc_tag_info":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false},"uagb_author_info":{"display_name":"rietiana@gmail.com","author_link":"https:\/\/kinerjabumdam.org\/fp\/author\/rietianagmail-com\/"},"uagb_comment_info":0,"uagb_excerpt":"23. PI_O_AM_01: Prosentase kapasitas produksi saat ini (%) (Percentage of Current Production Capacity) Definisi:\u00a0Perbandingan antara kapasitas produksi riil saat ini dengan kapasitas terpasang (desaiseluruh unit Instalasi Pengolahan Air (IPBUMD-AM. Rumus: Data yang Dibutuhkan: Sumber Data: 24. PI_O_AM_02: Tingkat Kehilangan Air Produksi (%) (Production Water Losses) Definisi:\u00a0Persentase selisih antara volume air baku yang diambil dengan volume&hellip;","_links":{"self":[{"href":"https:\/\/kinerjabumdam.org\/fp\/wp-json\/wp\/v2\/docs\/971","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/kinerjabumdam.org\/fp\/wp-json\/wp\/v2\/docs"}],"about":[{"href":"https:\/\/kinerjabumdam.org\/fp\/wp-json\/wp\/v2\/types\/docs"}],"author":[{"embeddable":true,"href":"https:\/\/kinerjabumdam.org\/fp\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/kinerjabumdam.org\/fp\/wp-json\/wp\/v2\/comments?post=971"}],"version-history":[{"count":5,"href":"https:\/\/kinerjabumdam.org\/fp\/wp-json\/wp\/v2\/docs\/971\/revisions"}],"predecessor-version":[{"id":2045,"href":"https:\/\/kinerjabumdam.org\/fp\/wp-json\/wp\/v2\/docs\/971\/revisions\/2045"}],"wp:attachment":[{"href":"https:\/\/kinerjabumdam.org\/fp\/wp-json\/wp\/v2\/media?parent=971"}],"wp:term":[{"taxonomy":"doc_category","embeddable":true,"href":"https:\/\/kinerjabumdam.org\/fp\/wp-json\/wp\/v2\/doc_category?post=971"},{"taxonomy":"doc_tag","embeddable":true,"href":"https:\/\/kinerjabumdam.org\/fp\/wp-json\/wp\/v2\/doc_tag?post=971"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}